Germany
 
de
en
 
Germany
 
de
en
 

Rectangular connector inserts

The core of your rectangular connector

Together with the contacts, the EPIC® rectangular connector inserts form the interior of a rectangular connector and are used for a wide range of applications in industry. Our portfolio consists of 11 series, which combine EPIC® rectangular connector inserts of the same type in different variants. We provide inserts for various connection techniques such as crimped, screw-in, push-in, cage clamp and solder connections, as well as inserts that are certified for foreign markets or special applications such as rail transport. Discover which insert is the perfect choice for your rectangular connectors!

Categories

Connectors
Rectangular connectors

Filter

Reset

Filter

Filter

Reset

  • General information
    • Product type
      • Crimping insert
      • Insert
      • Insert with cage spring termination
      • Insert with push-in connection
      • Insert with screw connection
      • Insert with solder termination
    • Brand
      • EPIC®
    • Design size
      • 10A
      • 10B
      • 16A
      • 16B
      • 24B
      • 32A
      • 32B
      • 3A
      • 48A
      • 48B
      • 6B
      • Q
    • Scope of delivery
      • Order contacts separately
      • including PE contacts
      • including contacts
      • including screws
      • without PE contacts
    • Contacts included
      • Yes
      • No
    • Weight
      • 0.06 kg
      • 0.048 kg
      • 0.07 kg
      • 0.088 kg
      • 0.008 kg
      • 0.061 kg
      • 0.12 kg
      • 0.014 kg
      • 0.055 kg
      • 0.065 kg
      • 0.009 kg
      • 0.019 kg
      • 0.04 kg
      • 0.1 kg
      • 0.015 kg
      • 0.02 kg
      • 0.049 kg
      • 0.05 kg
      • 0.071 kg
      • 0.075 kg
      • 0.08 kg
      • 0.09 kg
      • 0.092 kg
      • 0.01 kg
      • 0.016 kg
      • 0.018 kg
      • 0.021 kg
      • 0.022 kg
      • 0.024 kg
      • 0.043 kg
      • 0.045 kg
      • 0.047 kg
      • 0.058 kg
      • 0.059 kg
      • 0.063 kg
      • 0.072 kg
      • 0.085 kg
      • 0.095 kg
      • 0.109 kg
      • 0.128 kg
      • 0.004 kg
      • 0.013 kg
      • 0.023 kg
      • 0.033 kg
      • 0.037 kg
      • 0.039 kg
      • 0.046 kg
      • 0.051 kg
      • 0.057 kg
      • 0.062 kg
      • 0.067 kg
      • 0.068 kg
      • 0.073 kg
      • 0.077 kg
      • 0.078 kg
      • 0.079 kg
      • 0.084 kg
      • 0.086 kg
      • 0.087 kg
      • 0.107 kg
      • 0.11 kg
      • 0.112 kg
      • 0.114 kg
      • 0.115 kg
      • 0.116 kg
      • 0.117 kg
      • 0.012 kg
      • 0.017 kg
      • 0.034 kg
      • 0.042 kg
      • 0.052 kg
      • 0.053 kg
      • 0.056 kg
      • 0.064 kg
      • 0.066 kg
      • 0.069 kg
      • 0.081 kg
      • 0.082 kg
      • 0.083 kg
      • 0.093 kg
      • 0.094 kg
      • 0.098 kg
      • 0.105 kg
      • 0.111 kg
      • 0.118 kg
      • 0.121 kg
      • 0.123 kg
      • 0.14 kg
      • 0.142 kg
      • 0.183 kg
      • 0.194 kg
      • 0.274 kg
      • 0.276 kg
      • 0.28 kg
      • 0.285 kg
      • 0.305 kg
      • 0.323 kg
    • Product series
      • RECTANGULAR
      • HDC
    • Delivery Unit
      • 5.0
      • 1.0
      • 10.0
  • Electrical parameters
    • Rated voltage
      • 24 V AC rms / DC according to IEC
      • 24 V AC rms according to IEC
      • 48 V AC rms / DC according to CSA
      • 48 V AC rms / DC according to UL
      • 48 V AC rms / DC according to UL/CSA
      • 50 V AC rms / DC according to CSA
      • 50 V AC rms / DC according to UL
      • 50 V AC rms according to IEC
      • 60 V DC according to IEC
      • 60 V DC according to UL
      • 120 V DC according to UL
      • 230 V AC rms / DC according to IEC
      • 250 V AC rms / DC according to IEC
      • 250 V AC rms / DC according to UL
      • 250 V AC rms / DC according to CSA
      • 250 V AC rms according to IEC
      • 400 V AC rms / DC according to IEC
      • 400 V AC rms / DC according to CSA
      • 400 V AC rms / DC according to UL
      • 400 V AC rms / DC according to UL/CSA
      • 500 V AC rms / DC according to IEC
      • 600 V AC rms / DC according to UL
      • 600 V AC rms / DC according to CSA
      • 600 V AC rms / DC according to UL/CSA
      • 630 V AC rms / DC according to IEC
      • 830 V AC rms / DC according to IEC
      • 1000 V AC rms / DC according to IEC
    • Rated voltage power contact
      • 690 V AC rms / DC according to IEC to 6
      • 690 V AC rms / DC according to IEC to 4
      • 400 V AC rms / DC according to IEC to 4
      • 400 V AC rms / DC according to IEC to 8
      • 600 V AC rms / DC according to CSA to 4
      • 600 V AC rms / DC according to UL to 4
      • 690 V AC rms / DC according to IEC to 12
      • 690 V AC rms / DC according to IEC to 8
      • 400 V AC rms / DC according to IEC to 5
      • 830 V AC rms / DC according to IEC to 4
      • 830 V AC rms / DC according to IEC to 6
    • Rated voltage signal contact
      • 250 V AC rms / DC according to IEC to 2
      • 250 V AC rms / DC according to IEC to 4
      • 160 V AC rms / DC according to IEC to 24
      • 250 V AC rms / DC according to CSA to 2
      • 250 V AC rms / DC according to UL to 2
      • 400 V AC rms / DC according to IEC to 2
      • 160 V AC rms / DC according to IEC to 36
      • 400 V AC rms / DC according to IEC to 6
      • 400 V AC rms according to IEC to 6
      • 690 V AC rms / DC according to IEC to 36
    • Rated voltage core to core
      • 690 V AC rms / DC according to IEC
      • 400 V AC rms / DC according to IEC
    • Rated surge voltage
      • 6 kV AC rms / DC according to IEC 61984
      • 4 kV AC rms / DC according to IEC 61984
      • 2.5 kV AC rms / DC according to IEC 61984
      • 8 kV AC rms / DC according to IEC 61984
      • 4 kV AC rms / DC according to DIN EN 61984
    • Rated surge voltage power contact
      • 6 kV AC rms / DC according to IEC 61984 to 6
      • 8 kV AC rms / DC according to IEC 61984 to 4
      • 8 kV AC rms / DC according to IEC 61984 to 6
      • 4 kV AC rms / DC according to IEC 61984 to 8
      • 6 kV AC rms / DC according to IEC 61984 to 4
      • 8 kV AC rms / DC according to IEC 61984 to 12
      • 8 kV AC rms / DC according to IEC 61984 to 8
    • Rated impulse voltage signal contact
      • 4 kV AC rms / DC according to IEC 61984 to 12
      • 4 kV AC rms / DC according to IEC 61984 to 2
      • 4 kV AC rms / DC according to IEC 61984 to 4
      • 2.5 kV AC rms / DC according to IEC 61984 to 24
      • 2.5 kV AC rms / DC according to IEC 61984 to 36
      • 4 kV AC rms / DC according to IEC 61984 to 6
      • 6 kV AC rms / DC according to IEC 61984 to 6
    • Rated voltage core to earth
      • 400 V AC rms / DC according to IEC
      • 230 V AC rms / DC according to IEC
    • Rated current
      • 10 A according to CSA
      • 10 A according to IEC
      • 10 A according to UL
      • 10 A according to UL/CSA
      • 13 A according to UL
      • 13 A according to UL/CSA
      • 14 A according to UL
      • 16 A according to CSA
      • 16 A according to IEC
      • 16 A according to UL
      • 16 A according to UL/CSA
      • 20 A according to IEC
      • 22 A according to CSA
      • 23 A according to IEC
      • 30 A according to IEC
      • 30 A according to UL
      • 35 A according to IEC
      • 35 A according to UL
      • 35 A according to UL/CSA
      • 40 A according to CSA
      • 40 A according to IEC
      • 40 A according to UL
      • 44 A according to CSA
      • 8.5 A according to CSA
      • 8.5 A according to UL
      • 80 A according to IEC
      • 80 A according to UL/CSA
      • 85 A according to UL
    • Rated current connector
      • 10 A according to CSA
      • 10 A according to IEC
      • 10 A according to UL
      • 16 A according to CSA
      • 16 A according to IEC
      • 16 A according to UL
      • 30 A according to IEC
      • 35 A according to IEC
    • Rated current power contact
      • 40 A according to IEC
      • 100 A according to IEC
      • 63 A according to IEC
      • 80 A according to IEC
      • 16 A according to IEC
      • 40 A according to CSA
      • 40 A according to UL
    • Rated current signal contact
      • 10 A according to IEC
      • 16 A according to IEC
      • 10 A according to CSA
      • 10 A according to UL
    • Over voltage category
      • III
    • Max. contact resistance
      • 2 mΩ
      • 1 mΩ
      • 3 mΩ
      • 4 mΩ
      • 5 mΩ
      • 100 mΩ
    • Protective conductor integrated into insert
      • Yes
      • No
  • Product design
    • Number of contacts
      • 10+PE
      • 108+PE
      • 12+PE
      • 13
      • 14+PE
      • 15+PE
      • 16 + PE
      • 16+PE
      • 17
      • 18+PE
      • 2+PE
      • 24+PE
      • 25+PE
      • 3+PE
      • 32+PE
      • 4 + PE
      • 4+PE
      • 40 + PE
      • 40+PE
      • 42+PE
      • 46+PE
      • 5
      • 5+PE
      • 6
      • 6+PE
      • 64 + PE
      • 64+PE
      • 7
      • 7+PE
      • 72+PE
      • 8
      • 8+PE
      • 9
    • Number of power contacts
      • 6.0
      • 16.0
      • 10.0
      • 24.0
      • 4.0
      • 3.0
      • 2.0
      • 8.0
      • 40.0
      • 64.0
      • 5.0
      • 7.0
      • 12.0
      • 15.0
      • 25.0
      • 108.0
      • 72.0
      • 32.0
      • 42.0
      • 46.0
      • 18.0
      • 1.0
    • Number of PE contacts
      • 1.0
      • 0.0
      • 24.0
    • Number of signal contacts
      • 0.0
      • 2.0
      • 4.0
      • 6.0
      • 7.0
      • 12.0
      • 8.0
      • 24.0
      • 36.0
    • Contact diameter
      • 2.5 mm
      • 1.6 mm
      • 3.5 mm
      • 6.0 mm
    • Contact variant
      • Pin
      • Socket
    • Contact manufacturing method
      • Machined
      • Stamped
    • Contact insert type
      • Drain
      • Plug
      • Socket
    • With wire protection
      • No
      • Yes
    • With protective conductor
      • Yes
      • No
    • Connector type
      • Plug
      • Socket
    • Contact insert without contacts
      • No
      • Yes
    • Screen contact
      • No
    • EMC screening
      • Yes
      • No
    • Conductor connection type
      • Axial screw connection
      • Cage clamp terminal
      • Crimp termination
      • Push-in
      • Screw connection
      • Solder termination
    • Connection type PE
      • Screw connection
      • Crimp termination
      • Axial screw connection
      • Cage clamp terminal
      • Insulation displacement contact
    • Stripping length of the individual wire
      • 8.0 mm
      • 6.0 mm
      • 13.0 mm
      • 5.0 mm
      • 14.0 mm
      • 7.0 mm
    • Stripping length of PE
      • 8.0 mm
      • 6.0 mm
      • 7.0 mm
    • Connectable conductor cross section min. (AWG)
      • 12 AWG
      • 14 AWG
      • 16 AWG
      • 18 AWG
      • 20 AWG
      • 24 AWG
      • 26 AWG
    • Connectable conductor cross section max. (AWG)
      • 10 AWG
      • 12 AWG
      • 14 AWG
      • 16 AWG
      • 6 AWG
      • 8 AWG
    • Min. connectable conductor cross-section of power contacts (mm2)
      • 6.0 mm²
      • 2.5 mm²
      • 4.0 mm²
      • 10.0 mm²
      • 14.0 mm²
      • 16.0 mm²
    • Connectable conductor cross-section for power contacts max. (mm2)
      • 10.0 mm²
      • 8.0 mm²
      • 16.0 mm²
      • 22.0 mm²
      • 25.0 mm²
      • 35.0 mm²
    • Connectable conductor cross-section for signal contacts min. (mm2)
      • 0.14 mm²
      • 0.2 mm²
      • 0.22 mm²
      • 1.0 mm²
    • Max. connectable conductor cross-section of signal contacts (mm2)
      • 2.5 mm²
    • Min. connectable conductor cross-section (mm2)
      • 0.14 mm²
      • 0.5 mm²
      • 0.75 mm²
      • 1.0 mm²
      • 1.5 mm²
      • 2.5 mm²
      • 4.0 mm²
      • 6.0 mm²
    • Max. connectable conductor cross-section (mm2)
      • 0.14 mm²
      • 1.5 mm²
      • 2.5 mm²
      • 4.0 mm²
      • 6.0 mm²
      • 8.0 mm²
      • 10.0 mm²
      • 16.0 mm²
    • Insert material
      • Polycarbonate
      • Polyamide
    • Insert material, short form
      • PC
    • Material contact
      • Brass
      • Copper alloy
    • Contact material, short form
      • CuZn
      • CuSn
    • Material contact surface
      • Silver-plated
      • Tin-plated
    • Material contact surface shortname
      • Ag
    • Material contact insert
      • Polycarbonate
      • Polyamide
      • Polybutylene terephthalate
    • Contact insert material, short form
      • PC
      • PA
      • PBT
    • Colour
      • black
      • grey
  • Product features
    • Product features
      • Chemical resistant
      • Flame-retardant
      • Halogenfree
      • Impact-resistant
      • UV-resistant
      • Vibration protection
    • Min. number of plug cycles
      • 500
      • 100
      • 200
    • Pollution degree
      • 3
    • Short-term temperature peak
      • 125.0 °C
    • Operating temperature min.
      • -40.0 °C
      • 125.0 °C
    • Operating temperature max.
      • 100.0 °C
      • 125.0 °C
      • 120.0 °C
      • 80.0 °C
    • Flame retardance according to
      • UL 94 V-0
      • UL 94 V-2
    • Minimum tightening torque for PE connection
      • 1.2 Nm
      • 0.5 Nm
      • 1.8 Nm
      • 2.0 Nm
      • 0.25 Nm
    • Maximum tightening torque PE
      • 1.2 Nm
      • 0.5 Nm
      • 1.8 Nm
      • 2.0 Nm
      • 0.25 Nm
  • Certifications and standards
    • Certifications
      • CE marked
      • CSA certified
      • Tested for fire protection for railway vehicles
      • UR recognised
      • VDE certified
      • cUR recognized
    • EAC certified
      • Not required
    • EAC certification number
      • Отказное письмо № 39
    • UR certification
      • according to UL 1977 (e-file number: E75770)
      • according to UL 1977 (CCN: ECBT2 / e-file number: E75770)
      • according to UL 2237 (e-file number: E483837)
      • according to UL 1977 (CCN: ECBT2 / e-file number: 75770)
      • according to UL 1977 (CCN: ECBT8 / e-file number: E75770)
    • UL category control number
      • ECBT2
    • cUR certification
      • according to CSA C22.2 No. 182.3 (e-file number: E75770)
      • according to CSA C22.2 No. 182.3 (CCN: ECBT8 / e-file number: E75770)
      • according to CSA C22.2 No. 182.3 (CCN: ECBT8 / e-file number: 75770)
      • according to CSA C22.2 No. 182.2 (CCN: ECBT8 / e-file number: E75770)
      • according to CSA C22.2 No. 182.2 (e-file number: E75770)
      • according to CSA C22.2 No. 182.3 (CCN: CYJV8 / e-file number: 75770)
      • according to CSA C22.2 No. 182.3 (CCN: ECBT2 / e-file number: 75770)
      • according to CSA C22.2 No. 182.3 (CCN: ECBT2 / e-file number: E75770)
      • according to CSA C22.2 No. 182.3 (CCN: ECBT8)
    • cUR category control number
      • ECBT8
    • VDE registration number
      • B437
    • Product standard according to IEC
      • IEC 61984
    • Fire protection for railway vehicles hazard level
      • EN 45545-2 HL1
      • EN 45545-2 HL2
      • EN 45545-2 HL3
Results (85)