United States
 
 
United States
 
 

Halogen-free cables

For areas with increased fire hazard

Our halogen-free ÖLFLEX® power and control cables are used in public buildings, such as airports and railway stations, and wherever people, animals and valuable assets are exposed to high risk in the event of a fire. The halogen-free cables from LAPP are oil-resistant and flexible, as well as available in shielded or unshielded variants.

Categories

Cables and wires
Power and control cables

Filter

Reset

Filter

Filter

Reset

  • General information
    • Product type
      • Control cable
      • Power cable
    • Brand
      • ÖLFLEX®
    • Copper index (lb)
      • 193.5 lb/10,000 ft
      • 322.5 lb/10,000 ft
      • 483.8 lb/10,000 ft
      • 387.0 lb/10,000 ft
      • 1935.1 lb/10,000 ft
      • 129.0 lb/10,000 ft
      • 290.26 lb/10,000 ft
      • 290.3 lb/10,000 ft
      • 483.82 lb/10,000 ft
      • 677.3 lb/10,000 ft
      • 774.0 lb/10,000 ft
      • 806.3 lb/10,000 ft
      • 1161.0 lb/10,000 ft
      • 6450.2 lb/10,000 ft
      • 96.8 lb/10,000 ft
      • 145.1 lb/10,000 ft
      • 241.91 lb/10,000 ft
      • 258.0 lb/10,000 ft
      • 294.3 lb/10,000 ft
      • 342.7 lb/10,000 ft
      • 354.8 lb/10,000 ft
      • 357.5 lb/10,000 ft
      • 409.9 lb/10,000 ft
      • 451.5 lb/10,000 ft
      • 451.56 lb/10,000 ft
      • 580.5 lb/10,000 ft
      • 591.3 lb/10,000 ft
      • 645.0 lb/10,000 ft
      • 653.1 lb/10,000 ft
      • 690.7 lb/10,000 ft
      • 1128.8 lb/10,000 ft
      • 1290.0 lb/10,000 ft
      • 1548.1 lb/10,000 ft
      • 1612.6 lb/10,000 ft
      • 1741.6 lb/10,000 ft
      • 2378.5 lb/10,000 ft
      • 2418.8 lb/10,000 ft
      • 2580.1 lb/10,000 ft
      • 3225.1 lb/10,000 ft
      • 4031.4 lb/10,000 ft
      • 64.5 lb/10,000 ft
      • 96.75 lb/10,000 ft
      • 129.02 lb/10,000 ft
      • 161.25 lb/10,000 ft
      • 195.5 lb/10,000 ft
      • 225.75 lb/10,000 ft
      • 235.83 lb/10,000 ft
      • 235.86 lb/10,000 ft
      • 241.9 lb/10,000 ft
      • 258.036 lb/10,000 ft
      • 265.4 lb/10,000 ft
      • 278.16 lb/10,000 ft
      • 278.2 lb/10,000 ft
      • 288.9 lb/10,000 ft
      • 322.55 lb/10,000 ft
      • 329.2 lb/10,000 ft
      • 329.26 lb/10,000 ft
      • 338.64 lb/10,000 ft
      • 338.672 lb/10,000 ft
      • 349.42 lb/10,000 ft
      • 350.05 lb/10,000 ft
      • 387.05 lb/10,000 ft
      • 402.46 lb/10,000 ft
      • 418.6 lb/10,000 ft
      • 422.0 lb/10,000 ft
      • 435.4 lb/10,000 ft
      • 464.3 lb/10,000 ft
      • 467.0 lb/10,000 ft
      • 483.76 lb/10,000 ft
      • 493.84 lb/10,000 ft
      • 510.6 lb/10,000 ft
      • 533.5 lb/10,000 ft
      • 551.0 lb/10,000 ft
      • 559.0 lb/10,000 ft
      • 576.5 lb/10,000 ft
      • 581.2 lb/10,000 ft
      • 614.1 lb/10,000 ft
      • 645.09 lb/10,000 ft
      • 671.97 lb/10,000 ft
      • 700.8 lb/10,000 ft
      • 712.9 lb/10,000 ft
      • 752.5 lb/10,000 ft
      • 774.02 lb/10,000 ft
      • 774.108 lb/10,000 ft
      • 774.11 lb/10,000 ft
      • 792.8 lb/10,000 ft
      • 827.8 lb/10,000 ft
      • 869.4 lb/10,000 ft
      • 870.8 lb/10,000 ft
      • 901.7 lb/10,000 ft
      • 902.4 lb/10,000 ft
      • 917.1 lb/10,000 ft
      • 987.7 lb/10,000 ft
      • 1032.0 lb/10,000 ft
      • 1032.03 lb/10,000 ft
      • 1032.14 lb/10,000 ft
      • 1058.2 lb/10,000 ft
      • 1063.6 lb/10,000 ft
      • 1133.5 lb/10,000 ft
      • 1136.2 lb/10,000 ft
  • Electrical characteristics
    • Nominal voltage
      • U0/U: 300/500 V AC rms according to IEC
      • U0/U: 0,6/1 kV AC rms / DC according to IEC
      • U0/U: 300/500 V AC rms / DC according to IEC
      • U0/U: 450/750 V AC rms according to IEC
    • Rated voltage
      • 600 V AC rms according to UL AWM
      • 1000 V AC rms according to UL AWM
    • Test voltage
      • 4 kV
    • Test voltage conductor/conductor
      • 4 kV
    • Test voltage conductor/shielding
      • 4 kV
      • 3 kV
      • 2 kV
  • Product design
    • Basic material of outer jacket
      • Halogen-free compound
    • Basic material of outer jacket, short form
      • HFFR
    • Cable dimensions
      • 3G2.5
      • 3G1.5
      • 4G1.5
      • 4G2.5
      • 4G4
      • 5G1
      • 7G1
      • 12G1
      • 3G1
      • 4G10
      • 4G25
      • 4G6
      • 5G1.5
      • 5G2.5
      • 7G1.5
      • 12G1.5
      • 12G2.5
      • 18G1
      • 18G1.5
      • 25G1
      • 25G1.5
      • 2X1
      • 2X1.5
      • 4G1
      • 4G16
      • 5G4
      • 5G6
      • 7G2.5
      • 12G0.75
      • 25G2.5
      • 2X0.5
      • 3G0.5
      • 3G4
      • 3G6
      • 3X0.75
      • 4G0.5
      • 4G0.75
      • 4X0.5
      • 4X0.75
      • 5G10
      • 12G0.5
      • 18G0.75
      • 18G2.5
      • 2X2.5
      • 3G0.75
      • 3X0.5
      • 3X1
      • 3X1.5
      • 4G35
      • 5G0.5
      • 5G0.75
      • 5G16
      • 5X1
      • 7G0.5
      • 7G4
      • 7G6
      • 10G0.75
      • 14G1.5
      • 25X1
      • 2X0.75
      • 4G70
      • 4X1
      • 4X1.5
      • 5G35
      • 5X0.75
      • 7G0.75
      • 7X0.75
      • 7X1
      • 8G1.5
      • 9G0.75
    • Cable form
      • Round
    • Conductor color code
      • EN 50334
      • VDE 0293-1
      • VDE 0293-308
    • Conductor design
      • IEC 60228 class 5: fine-wire
    • Conductor identification
      • Numbers
      • Colors
    • Conductor insulation basic material
      • Halogen-free compound
    • Conductor insulation basic material, short form
      • HFFR
    • Conductor material
      • Bare Copper
    • Including protective conductor
      • Yes
      • No
    • Leading conductor cross-section
      • mm²
    • Nominal conductor cross-section (AWG)
      • 2 AWG
      • 4 AWG
      • 6 AWG
      • 8 AWG
      • 10 AWG
      • 12 AWG
      • 14 AWG
      • 16 AWG
      • 18 AWG
      • 19 AWG
      • 21 AWG
    • Nominal conductor cross-section (metric)
      • 1.0 mm²
      • 1.5 mm²
      • 2.5 mm²
      • 0.75 mm²
      • 0.5 mm²
      • 4.0 mm²
      • 6.0 mm²
      • 10.0 mm²
      • 16.0 mm²
      • 25.0 mm²
      • 35.0 mm²
      • 70.0 mm²
    • Nominal outer diameter
      • 0.398 in
      • 0.26 in
      • 0.327 in
      • 0.354 in
      • 0.228 in
      • 0.24 in
      • 0.268 in
      • 0.291 in
      • 0.315 in
      • 0.386 in
      • 0.638 in
      • 0.74 in
      • 0.248 in
      • 0.272 in
      • 0.28 in
      • 0.287 in
      • 0.319 in
      • 0.339 in
      • 0.358 in
      • 0.378 in
      • 0.409 in
      • 0.425 in
      • 0.449 in
      • 0.492 in
      • 0.5 in
      • 0.512 in
      • 0.587 in
      • 0.591 in
      • 0.681 in
      • 0.213 in
      • 0.295 in
      • 0.299 in
      • 0.331 in
      • 0.335 in
      • 0.35 in
      • 0.382 in
      • 0.413 in
      • 0.441 in
      • 0.457 in
      • 0.461 in
      • 0.476 in
      • 0.48 in
      • 0.496 in
      • 0.528 in
      • 0.535 in
      • 0.551 in
      • 0.555 in
      • 0.594 in
      • 0.634 in
      • 0.677 in
      • 0.701 in
      • 0.736 in
      • 0.791 in
      • 0.925 in
      • 0.201 in
      • 0.217 in
      • 0.232 in
      • 0.244 in
      • 0.252 in
      • 0.366 in
      • 0.37 in
      • 0.394 in
      • 0.406 in
      • 0.421 in
      • 0.429 in
      • 0.433 in
      • 0.437 in
      • 0.445 in
      • 0.453 in
      • 0.465 in
      • 0.469 in
      • 0.472 in
      • 0.508 in
      • 0.524 in
      • 0.539 in
      • 0.559 in
      • 0.567 in
      • 0.571 in
      • 0.575 in
      • 0.579 in
      • 0.583 in
      • 0.606 in
      • 0.618 in
      • 0.622 in
      • 0.626 in
      • 0.63 in
      • 0.661 in
      • 0.685 in
      • 0.705 in
      • 0.713 in
      • 0.752 in
      • 0.78 in
      • 0.795 in
      • 0.803 in
      • 0.815 in
      • 0.831 in
      • 0.843 in
      • 0.854 in
      • 0.866 in
      • 0.878 in
    • Number of conductors
      • 4.0
      • 3.0
      • 5.0
      • 7.0
      • 12.0
      • 2.0
      • 18.0
      • 25.0
      • 8.0
      • 9.0
      • 10.0
      • 14.0
    • Outer jacket color
      • gray
      • black
    • Shielded
      • No
      • Yes
    • Stranding type
      • Layered Stranding
    • Type of overall shielding
      • Tin-plated copper braiding
  • Product features
    • Characteristics
      • Flame-retardant
      • For torsional load
      • Halogen-free
      • Oil-resistant
      • Ozone-resistant
      • PWIS-free
      • UV-resistant
    • Application area
      • Fixed Installation
      • Flexible
    • Corrosiveness of combustion gases according to
      • IEC 60754-2
    • Flame retardance according to
      • IEC 60332-1-2
      • UL Cable Flame Test
      • IEC 60332-3-22
      • IEC 60332-3-25
      • IEC 60332-3-24
      • UL Horizontal Flame Test
    • Halogen-free according to
      • IEC 60754-1
    • Low smoke density according to
      • IEC 61034-2
    • Low toxicity of combustion gases according to
      • NES 02-713 (≤ 3)
      • EN 50306-1 (≤ 3)
    • Minimum bending radius in inch, occasionally moved
      • 2.283 in
      • 4.724 in
      • 5.965 in
      • 11.102 in
      • 5.079 in
      • 5.197 in
      • 5.315 in
      • 2.48 in
      • 2.717 in
      • 4.37 in
      • 5.787 in
      • 6.732 in
      • 2.402 in
      • 2.598 in
      • 2.677 in
      • 2.953 in
      • 3.189 in
      • 3.268 in
      • 3.543 in
      • 3.602 in
      • 3.976 in
      • 4.016 in
      • 4.252 in
      • 4.311 in
      • 4.783 in
      • 4.902 in
      • 5.02 in
      • 5.118 in
      • 5.591 in
      • 5.669 in
      • 5.728 in
      • 6.201 in
      • 6.378 in
      • 6.535 in
      • 7.382 in
      • 7.402 in
      • 7.441 in
      • 7.5 in
      • 8.031 in
      • 8.189 in
      • 8.268 in
      • 8.799 in
      • 9.134 in
      • 11.043 in
      • 12.756 in
      • 13.622 in
      • 15.827 in
      • 2.008 in
      • 2.126 in
      • 2.165 in
      • 2.52 in
      • 2.874 in
      • 2.913 in
      • 2.992 in
      • 3.583 in
      • 3.78 in
      • 4.193 in
      • 4.213 in
      • 4.409 in
      • 4.646 in
      • 4.764 in
      • 4.803 in
      • 4.882 in
      • 4.961 in
      • 5.256 in
      • 5.276 in
      • 5.374 in
      • 5.492 in
      • 5.709 in
      • 5.748 in
      • 5.906 in
      • 5.945 in
      • 5.984 in
      • 6.083 in
      • 6.142 in
      • 6.299 in
      • 6.496 in
      • 6.555 in
      • 6.614 in
      • 6.673 in
      • 6.772 in
      • 6.791 in
      • 6.909 in
      • 7.008 in
      • 7.126 in
      • 7.165 in
      • 7.205 in
      • 7.717 in
      • 7.854 in
      • 7.874 in
      • 8.091 in
      • 8.504 in
      • 8.583 in
      • 8.74 in
      • 8.819 in
      • 8.858 in
      • 8.917 in
      • 9.213 in
      • 9.252 in
      • 9.272 in
    • Minimum bending radius in inch, stationary
      • 1.591 in
      • 0.913 in
      • 1.417 in
      • 1.89 in
      • 0.961 in
      • 1.071 in
      • 1.307 in
      • 1.559 in
      • 1.984 in
      • 0.992 in
      • 1.087 in
      • 1.15 in
      • 1.276 in
      • 1.512 in
      • 1.677 in
      • 1.701 in
      • 1.748 in
      • 2.031 in
      • 2.961 in
      • 3.827 in
      • 4.087 in
      • 0.85 in
      • 1.039 in
      • 1.165 in
      • 1.181 in
      • 1.543 in
      • 1.795 in
      • 1.921 in
      • 1.961 in
      • 2.008 in
      • 2.047 in
      • 2.102 in
      • 2.15 in
      • 2.315 in
      • 2.362 in
      • 2.378 in
      • 2.457 in
      • 2.48 in
      • 2.646 in
      • 2.693 in
      • 2.74 in
      • 2.945 in
      • 2.953 in
      • 3.0 in
      • 3.213 in
      • 3.331 in
      • 3.52 in
      • 3.543 in
      • 3.701 in
      • 4.063 in
      • 4.205 in
      • 4.748 in
      • 0.803 in
      • 0.866 in
      • 1.008 in
      • 1.197 in
      • 1.354 in
      • 1.394 in
      • 1.433 in
      • 1.465 in
      • 1.528 in
      • 1.638 in
      • 1.685 in
      • 1.732 in
      • 1.764 in
      • 1.78 in
      • 1.843 in
      • 1.906 in
      • 1.969 in
      • 2.0 in
      • 2.094 in
      • 2.11 in
      • 2.126 in
      • 2.157 in
      • 2.197 in
      • 2.205 in
      • 2.22 in
      • 2.268 in
      • 2.283 in
      • 2.291 in
      • 2.299 in
      • 2.346 in
      • 2.433 in
      • 2.52 in
      • 2.535 in
      • 2.551 in
      • 2.575 in
      • 2.709 in
      • 2.717 in
      • 2.764 in
      • 2.787 in
      • 2.811 in
      • 2.85 in
      • 2.858 in
      • 3.071 in
      • 3.165 in
      • 3.26 in
      • 3.307 in
      • 3.323 in
      • 3.354 in
    • Minimum bending radius, fixed installation
      • 4 x outer diameter
      • 6 x outer diameter
    • Minimum bending radius, occasionally flexing
      • 15 x outer diameter
      • 10 x outer diameter
      • 20 x outer diameter
    • Oil resistance according to
      • EN 50363-4-1: TM5
      • UL OILRES I
      • UL OILRES II
    • Ozone-resistant according to
      • EN 50396, method B
    • PWIS-free according to
      • VDMA 24364-B2-L
    • Temperature, fixed installation
      • -40 °C to 80 °C
      • to 75 °C according to UL AWM
    • Temperature, occasionally flexing
      • to 75 °C according to UL AWM
      • -30 °C to 70 °C
      • -25 °C to 70 °C
      • -5 °C to 70 °C
    • UV-resistant according to
      • EN 50620
      • DIN EN ISO 4892-2 method A
      • EN 50525-1 (cables with a black jacket are suitable for permanent outdoor use)
      • EN 50618
  • Certifications and standards
    • Certificates
      • CE marking
      • DNV-certified
      • UKCA marked
      • UL recognized
    • CPR acidity
      • a1
      • a3
    • CPR drip behavior
      • d1
      • d2
    • CPR fire class
      • Dca
      • Cca
      • B2ca
      • Eca
    • CPR smoke density
      • s1
      • s3
      • s1b
      • s2
      • s1a
    • DNV certificate number
      • TAE0000407
      • TAE0000408
      • TAE00002RK
      • TAE00002RJ
    • EAC certification number
      • ЕАЭС N RU Д-DE.АЮ64.В.00130/20
      • С-DE.АЮ64.В.01077
      • ЕАЭС RU С-DE.АЮ64.В.00091/19
    • EAC-certified
      • Yes
    • UL AWM certification
      • 21089 according to UL 758 (e-file number: E63634)
      • 21156 according to UL 758 (e-file number: E63634)
      • 21217 according to UL 758 (e-file number: E63634)
Results (8)