Germany
 
de
en
 
Germany
 
de
en
 

Coaxial cables

For the transmission of high frequency signals

The RG (according to MIL-DTL 17 H) and RGB cables from LAPP can be used for high frequency data transmission. The coaxial cables are designed for fixed and limited flexible installation and can be used in enclosed rooms and outdoors at temperatures of up to -55°C to +250°C.

Categories

Cables

Filter

Reset

Filter

Filter

Reset

  • General information
    • Product type
      • Coaxial cables
    • Brand
      • UNITRONIC®
    • Weight
      • 17 kg/km
      • 100 kg/km
      • 116 kg/km
      • 12 kg/km
      • 130 kg/km
      • 132 kg/km
      • 140 kg/km
      • 157 kg/km
      • 170 kg/km
      • 207 kg/km
      • 38 kg/km
      • 52 kg/km
      • 57 kg/km
      • 60 kg/km
      • 9 kg/km
      • 97 kg/km
    • Copper index
      • 55.5 kg/km
      • 4.4 kg/km
      • 5.4 kg/km
      • 7.3 kg/km
      • 8.3 kg/km
      • 19.1 kg/km
      • 25.0 kg/km
      • 26.0 kg/km
      • 29.0 kg/km
      • 38.5 kg/km
      • 50.0 kg/km
      • 51.0 kg/km
      • 60.0 kg/km
      • 72.0 kg/km
      • 75.8 kg/km
      • 117.8 kg/km
  • Electrical parameters
    • Nominal voltage
      • U0/U: 2/2 kV AC rms according to IEC
    • Nominal characteristic impedance
      • 100 Ω
      • 50 Ω
      • 75 Ω
    • tolerance of nominal characteristic impedance
      • +/- 2Ω
      • +/- 3Ω
      • +/- 5Ω
  • Product design
    • Type of coaxial cables
      • RG 11 A/U
      • RG 174 A/U
      • RG 178 B/U
      • RG 187 A/U
      • RG 188 A/U
      • RG 213 /U
      • RG 214 /U
      • RG 223 /U
      • RG 58 C/U
      • RG 59 B/U
      • RG 6 A/U
      • RG 62 A/U
      • RG FD
      • RGB CY
      • RGB DY
    • Conductor count/size
      • 2
      • RG-59 B/U
      • RGB CY 3XKX0,4/1,8+3X0,25
      • RGB DY 5xKx0,4/1,8
      • RGB FD 3xKx0,6L/2,4
    • Cable dimension
      • 0.14
      • 0.5
      • 0.64
      • 0.89
      • 0.9
      • 3.17
      • 30 AWG
    • Conductor cross-section (mm2)
      • 0.057 mm²
      • 0.14 mm²
      • 0.16 mm²
      • 0.5 mm²
      • 0.64 mm²
      • 0.89 mm²
      • 0.9 mm²
      • 3.17 mm²
    • Nominal cross section conductor (AWG)
      • 26 AWG
      • 30 AWG
    • Nominal diameter conductor (mm)
      • 0.3 mm
      • 0.4 mm
      • 0.48 mm
      • 0.51 mm
      • 0.57 mm
      • 0.58 mm
      • 0.6 mm
      • 0.64 mm
      • 0.72 mm
      • 0.89 mm
      • 0.9 mm
      • 1.2 mm
      • 2.25 mm
      • 2.3 mm
    • Leading conductor cross-section
      • mm²
      • AWG
    • Number of wires
      • 1
      • 19
      • 7
    • Conductor design
      • 19-wire
    • Including protective conductor
      • No
    • Concentric conductor
      • Yes
    • Shielded
      • Yes
    • Type of overall screen
      • Tin-plated copper braiding
      • Copper braiding
    • Optical degree of coverage outer conductor
      • 95 %
    • With rodent protection
      • No
    • Nominal core diameter
      • 1.52 mm
      • 2.95 mm
      • 7.25 mm
      • 7.3 mm
      • 0.86 mm
      • 1.6 mm
      • 3.7 mm
      • 4.7 mm
    • Nominal outer diameter
      • 1.91 mm
      • 2.76 mm
      • 2.8 mm
      • 4.95 mm
      • 5.5 mm
      • 6.15 mm
      • 8.0 mm
      • 8.4 mm
      • 9.5 mm
      • 10.3 mm
      • 10.5 mm
      • 10.8 mm
      • 12.1 mm
    • Shape of cable
      • Round
    • inner conductor material
      • Bare Copper
      • Copper-plated Steel
      • Silver-plated Copper
      • Tin-plated Copper
      • Silver-plated Steel-copper Composite
      • Steel-copper Composite
    • Dieletric shortname
      • PE
    • Outer conductor
      • Copper braiding
      • Silver-plated copper braiding
      • Tin-plated copper braiding
    • Outer conductor second layer
      • Silver-plated copper braiding
    • Basic material of inner sheath
      • Polyvinylchloride
    • Basic material of inner sheath, short form
      • PVC
    • Base material of outer sheath
      • Fluoroethylene propylene
      • Polytetrafluoroethylene
      • Polyurethane
      • Polyvinylchloride
    • Base material of outer sheath, shortname
      • FEP
      • PTFE
      • PUR
      • PVC
    • Cable sheath colour
      • black
      • transparent
      • white
  • Product features
    • Product features
      • Flame-retardant
      • For continuous flexing
    • Application area
      • Cable chain
      • Fixed Installation
    • Minimum bending radius, fixed installation
      • 6 x outer diameter
    • Minimum bending radius in mm, stationary
      • 11.5 mm
      • 16.6 mm
      • 16.8 mm
      • 29.7 mm
      • 33.0 mm
      • 36.9 mm
      • 50.4 mm
      • 61.8 mm
      • 64.8 mm
      • 72.6 mm
    • Minimum bending radius, occasionally moved
      • 10 x outer diameter
      • 20 x outer diameter
    • Minimum bending radius in mm, occasionally flexing
      • 19.1 mm
      • 27.6 mm
      • 28.0 mm
      • 49.5 mm
      • 55.0 mm
      • 61.5 mm
      • 84.0 mm
      • 103.0 mm
      • 108.0 mm
      • 121.0 mm
      • 123.0 mm
    • Temperature, fixed installation
      • -40 °C to 80 °C
      • -55 °C to 250 °C
    • Flame retardance according to
      • IEC 60332-1-2
  • Certifications and standards
    • Certifications
      • CE marked
      • Flame retardance tested according to UN/ECE-R118
      • UKCA marked
    • EAC certified
      • Yes
    • EAC certification number
      • ЕАЭС N RU Д-DE.АЮ64.В.00130/20, ЕАЭС N RU Д-DE.РА01.В.47116/21
Results (3)